Always-On Backup for Communication Equipment
Telecom & Networking Battery Manufacturer India
Get an Instant Quote on WhatsAppLast updated: · Reviewed by the Leolus Energy engineering team, Bangalore.
When the power cuts, communication can't. Leolus Energy is an Indian telecom battery supplier and manufacturer building custom lithium batteries and backup packs for telecom and networking equipment — keeping routers, access points and communication devices online through outages, a growing need as homes and businesses depend on always-on connectivity.
From router UPS to wireless access points and telecom backup power, we build packs for long backup runtime, clean cut-over and the long cycle life that always-on infrastructure needs. As a factory-direct telecom battery supplier, we serve operators, ISPs and network-equipment OEMs across India without importer mark-ups or long lead times.
Telecom & Networking We Power
Router UPS
Mini-UPS lithium packs that keep Wi-Fi routers and ONTs online through power cuts.
Communication Devices
Reliable batteries for portable and fixed communication equipment.
Wireless Access Points
Backup packs for wireless access points needing uninterrupted uptime.
Network Equipment
Lithium backup for switches, gateways and edge network devices.
Fiber Communication Systems
Dependable packs for fiber and last-mile communication hardware.
Telecom Backup Power
Scalable lithium backup for telecom nodes and field equipment.
What a Telecom Backup Battery Specification Has to Pin Down
Most enquiries we receive specify capacity and voltage and stop there. For telecom & networking the parameters below decide whether the pack survives its intended service life, and they are the ones worth agreeing before a purchase order.
| Parameter | Typical requirement | Why it decides the outcome |
|---|---|---|
| Autonomy at site load | Hours of backup at the site's actual measured draw | Design load and measured load differ, often substantially, once every card and radio in the cabinet is counted. |
| Float life at cabinet temperature | Calendar life quoted at real, not nominal, temperature | Telecom cabinets in Indian summers run well above 40°C. Every 10°C above 25°C roughly halves calendar life; sizing at 25°C is a fiction. |
| Cabinet footprint and weight | Fits existing rack and floor loading | Lithium retrofits into cabinets built for lead-acid are usually constrained by mounting geometry, not by capacity. |
| Remote monitoring | SNMP or protocol-level integration with the NOC | A backup battery whose health is invisible to the network operations centre gets discovered at the worst possible moment. |
| Charge current limit | Matched to the rectifier | Lithium accepts charge far faster than lead-acid. A retrofit that does not limit charge current can exceed what the existing rectifier can deliver. |
Three Mistakes We See Repeatedly
These come up often enough in telecom & networking projects that they are worth stating plainly. None of them are exotic; all of them are expensive to discover after tooling is committed.
Direct lead-acid substitution
Voltage windows, charge profiles and low-voltage disconnect points all differ. A drop-in swap without reconfiguring the rectifier and the controller shortens pack life dramatically.
Sizing to nameplate load
Measure the actual site draw over a week. Nameplate figures are consistently conservative in one direction and optimistic in another.
No thermal plan
A lithium retrofit that solves the weight problem but ignores cabinet temperature simply moves the failure from year eight to year three.
If you are working through a specification and want a second opinion before committing, send it over — we would rather flag a problem at the drawing stage than build to a spec we know will disappoint. See how our custom pack process works.
Telecom & Networking Batteries — FAQs
Need a custom telecom & networking battery? Let's build it.
See how our custom battery pack process works — spec, prototype, production.